Articles tagged as “Compton Effect”

Study of the 137Cs spectrum: the backscatter peak and X rays

Download printable version Difficult Execution Time Data Analysis Radioactive Sources Yes Yes Hardware setupThis experiment guide is referred to the SP5640 educational kit. If you don’t have this kit, choose your own from the following list to visualize the related experiment guide:SG6118B - Emulation KitEquipmentSP5640 - Backpack DetectorAdditional Gamma Radioactive Source Purpose of the

Photonuclear cross-section / Compton Scattering cross-section

Download printable version Difficult Execution Time Data Analysis Radioactive Sources No Yes Hardware required to perform this experimentTo follow along with this experiment you must have an SP5630EN/ENP educational kit. If you don't have this kit, choose one below:SG6117A - Educational Gamma Kit,SG6117B - Emulation Kit,SG6117E - Backpack Detector EquipmentSP5630EN/ENP - Enviromental Kit Additional

Study of the 137Cs spectrum: the backscatter peak and X rays

Download printable version Difficult Execution Time Data Analysis Radioactive Sources Yes Yes Hardware setup This experiment guide is referred to the SP5600EMU educational kit. Equipment SP5600EMU- Emulation Kit Additional Gamma Radioactive Source This experiment is also possible with the following kits: SP5600C, SP5600AN, SP5640, SP5630EN, SP5600ENP. Purpose of the experiment Study the characteristics of

Photonuclear cross-section / Compton Scattering cross-section

Download printable version Difficult Execution Time Data Analysis Radioactive Sources Yes Yes Hardware setupThis experiment guide is referred to the SP5600EMU educational kit. If you don’t have this kit, choose your own from the following list to visualize the related experiment guide:SG6117A - Gamma / Premium Kit,SG6117C - Enviromental Kit,SG6117E - Backpack DetectorEquipmentSP5600EMU -

Photonuclear cross-section / Compton Scattering cross-section

Download printable version Difficult Execution Time Data Analysis Radioactive Sources No Gamma Hardware setupThis experiment guide is referred to the SP5600EMU educational kit. If you don’t have this kit, choose your own from the following list to visualize the related experiment guide:SG6117A - Gamma / Premium Kit,SG6117B - Emulation Kit,SG6117C - Enviromental KitEquipmentSP5640 -

Photonuclear cross-section / Compton Scattering cross-section

Download printable version Difficult Execution Time Data Analysis Radioactive Sources No Yes Hardware setup This experiment guide is referred to the SP5600C educational kit. Equipment SP5600C/AN - Educational Gamma Kit Additional Gamma Radioactive Source This experiment is also possible with the following kits: SP5600AN, SP5630ENP, SP5640, SP5630EN. Purpose of the experiment Determination of the