All CAEN Experiments

Quantum Nature of Light

Download printable version Difficult Execution Time Data Analysis Radioactive Sources No  No  Hardware setup This experiment guide is referred to the SP5600E/AN Educational Kit. Equipment: SP5600E - Educational Photon Kit Model SP5600 DT5720A SP5601 SP5650C Description Power Supply and Amplification Unit Desktop Digitizer 250 MS/s LED Driver Sensor Holder for SP5600 with SiPM Purpose

Muons Vertical Flux on Horizontal Detector

CAEN Educational
SG6212A
Categories: CAEN Experiments, Particle Physics | Tags: Cosmic Rays, Cosmics, muons, Muons Detection

Download printable version Difficult Execution Time Data Analysis Radioactive Sources No Yes Hardware setup This experiment guide is referred to the SP5600AN/D educational kit. If you don’t have this kit, choose your own from the following list to visualize the related experiment guide: SP5620CH - Cosmic Hunter Equipment: SP5600D - Educational Beta Kit Model

Muons Detection

CAEN Educational
SG6211A
Categories: CAEN Experiments, Cosmic Rays | Tags: Cosmic Rays, Cosmics, muons, Muons Detection

Download printable version Difficult Execution Time Data Analysis Radioactive Sources No No Hardware setupThis experiment guide is referred to the SP5600D educational kit. If you don’t have this kit, choose your own from the following list to visualize the related experiment guide: SG6211D - Cosmic HunterEquipment: SP5600D - Educational Beta KitModelSP5600DT5720ASP5608DescriptionPower Supply and Amplification

Spatial Resolution

Download printable version Difficult Execution Time Data Analysis Radioactive Sources Yes Yes Hardware setupThis experiment guide is referred to the SP5700 educational kit.Equipment: SP5700 - EasyPETModelSP5700Additional ToolDescriptionEasyPET22Na Radioactive source (recommended: 1/2 inch disc, 10 μCi) Purpose of the experimentEvaluation of the spatial resolution of a PET system composed of two detector modules.FundamentalsThe main goal

Two-dimensional Reconstruction of a Radioactive Source

Download printable version Difficult Execution Time Data Analysis Radioactive Sources No Yes Hardware setup This experiment guide is referred to the SP5700 educational kit. Equipment: SP5700 - EasyPET Model SP5700 Additional Tool Description EasyPET 22Na Radioactive source (recommended: 1/2 inch disc, 10 μCi) Purpose of the experiment Understanding the technique of the nuclear imaging

Positron Annihilation Detection

Download printable version Difficult Execution Time Data Analysis Radioactive Sources No Yes Hardware setup This experiment guide is referred to the SP5701 educational kit. Equipment: SP5701 - EasyPET Kit Model SP5700 DT5770 Additional Tool Description EasyPET Desktop Multi-Channel Analyzer 22Na Radioactive source (recommended: 1/2 inch disc, 10 μCi) Purpose of the experiment Positron annihilation

Basic Measurements: γ Spectroscopy and System Linearity

Download printable version   Difficult Execution Time Data Analysis Radioactive Sources Yes Yes Hardware setup This experiment guide is referred to the SP5701 educational kit. Equipment: SP5701 - EasyPET Kit Model SP5700 DT5770 Additional Tool Description EasyPET Desktop Multi-Channel Analyzer 22Na Radioactive source (recommended: 1/2 inch disc, 10 μCi) Purpose of the experiment Gamma

β-Radiation as a Method to Measure Paper Sheet Grammage and Thin Layer Thickness

Download printable version Difficult Execution Time Data Analysis Radioactive Sources Yes Yes Hardware setupThis experiment guide is referred to the SP5600D educational kit.Equipment: SP5600D - Educational Beta KitModelSP5600DT5720ASP5608Additional ToolDescriptionPower Supply and Amplification UnitDesktop Digitizer 250 MS/sScintillating tileβ Radioactive source Purpose of the experimentEstimation of the instrument sensitivity in the measurement of thin layer thickness

β-Radiation: Transmission through Matter

Download printable version Difficult Execution Time Data Analysis Radioactive Sources Yes Yes Hardware setup This experiment guide is referred to the SP5600D educational kit. Equipment: SP5600D - Educational Beta Kit Model SP5600 DT5720A SP5608 Additional Tool Description Power Supply and Amplification Unit Desktop Digitizer 250 MS/s Scintillating tile β Radioactive source Purpose of the

β-Spectroscopy

Download printable version Difficult Execution Time Data Analysis Radioactive Sources Yes Yes Hardware setupThis experiment guide is referred to the SP5600D educational kit.Equipment: SP5600D - Educational Beta KitModelSP5600DT5720ASP5608Additional ToolDescriptionPower Supply and Amplification UnitDesktop Digitizer 250 MS/sScintillating tileBeta Radioactive source Purpose of the experimentAfter gamma spectrometry, the student is introduced to the measurement and interpretation